Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Adicionar filtros








Intervalo de ano
1.
Chinese Journal of Laboratory Medicine ; (12): 697-704, 2023.
Artigo em Chinês | WPRIM | ID: wpr-995780

RESUMO

Objective:To investigate the distribution and related factors of lipoprotein(a) [Lp(a)] level in healthy Tajik and Kazak adults in China.Methods:A cross-sectional study was conducted from May to October 2021 and March to June 2022, and blood samples were collected from 2, 637 healthy Tajik adults [1 010 men, average age: (40.08±14.74) years; 1 627 women, average age: (38.27±12.90) years] in Tashkurgan Tajik Autonomous County and 1 911 healthy Kazak adults [720 men, average age: (42.10±12.26) years; 1 191 women, average age: (38.27±12.90) years] in Fuyun County of Xinjiang. Fasting blood glucose (FBG), creatinine (Cr), total cholesterol (TC), triglycerides (TG), high-density lipoprotein cholesterol (HDL-C), and Lp(a) were measured. The distribution of Lp(a) levels in different sex and age groups was compared. The Lp(a) level of Tajik and Kazakh ethnic groups was compared by Mann-Whitney U test, and correlation factors of Lp(a) level were analyzed by multiple logistic regression. Results:The distribution of Lp(a) level in Tajik and Kazak population was skewed. Lp(a) levels of Tajik and Kazak ranged from the lowest 0.40 mg/L and 0.62 mg/L to the highest 1 229.40 mg/L and 2 108.58 mg/L, respectively, and the median Lp(a) level was 78.90 (38.60, 190.20) mg/L and 103.30 (49.57, 234.27) mg/L, respectively. Median Lp(a) level of Kazak was significantly higher than that of Tjik ( P<0.001). The median Lp(a) levels of Tajik males and females were similar: 77.45 (39.80, 187.10) mg/L and 79.90 (38.60, 192.30) mg/L ( P=0.948). The median Lp(a) levels of Kazakh males and females were also similar: 109.42 (50.49, 230.38) mg/L and 99.01 (49.11, 237.25) mg/L, respectively ( P=0.578). After pooling the data of Tajik and Kazak and adjusting for age, sex, BMI, smoking, drinking, blood pressure, blood glucose and other factors, Lp(a) level was correlated with ethnic (standard partial regression coefficient 0.066, P=0.008) and LDL-C level (standard partial regression coefficient 0.136, P<0.001). Conclusions:Lp(a) level in healthy Tajik and Kazak adults varied greatly among individuals, and Kazak residents had a higher Lp(a) level than Tajik residents. There was no significant sex difference in Lp(a) level among Tajik and Kazakh, and LDL-C and ethnicity are independent factors related to Lp(a) level.

2.
Chinese Journal of Urology ; (12): 540-541, 2021.
Artigo em Chinês | WPRIM | ID: wpr-911065

RESUMO

The placement of the flexible ureteroscopic sheath during lithotripsy may injure the ureter. We have developed a double-tube flexible ureteral access sheath. Thirteen patients with renal calculi were treated with double-tube and flexible sheath in one stage. CT examination of 13 cases showed that the ureter was normal. The double-tube flexible ureteral access sheath makes the operation of sheathing easy, safe and effective.

3.
Chinese Journal of Geriatric Heart Brain and Vessel Diseases ; (12): 623-626, 2018.
Artigo em Chinês | WPRIM | ID: wpr-709173

RESUMO

Objective To study the influencing factors of clinical outcome in elderly acute ischemic stroke (AIS) patients after intravenous thrombolysis.Methods One hundred and fifty-one AIS patients admitted to our hospital for intravenous thrombolysis were divided into good outcome group (n=77) and poor outcome group (n=74) according to their modified Rankin scale score 3 months after the onset of AIS.The baseline data,thrombolysis time window,NIHSS score and ischemic stroke typing before thrombolysis,early symptom improvement,cerebral hemorrhage after thrombolysis were compared between the two groups.Results The serum levels of blood glucose and CRP,NIHSS score≥9 before thrombolysis,incidence of AF and cerebral hemorrhage were significantly higher in poor outcome group than in good outcome group (P< 0.05,P<0.01).Multivariate logistic regression analysis showed that NIHSS score,OCSP typing,blood glucose before thrombolysis,24 h symptom improvement were the independent influencing factors of clinical outcome in elderly AIS patients (OR =1.262,95 % CI:1.075-1.482,P =0.005;OR =0.203,95%CI:0.066-0.628,P=0.006;OR=1.264,95%CI:1.042-1.532,P=0.017;OR=25.764,95%CI:5.131-129.361,P=0.000).Conclusion NIHSS score,OCSP typing,blood glucose before thrombolysis and 24 h symptom improvement are the independent influencing factors of clinical outcome in elderly AIS patients after intravenous thrombolysis.

4.
Chinese Journal of Medical Imaging ; (12): 531-535, 2017.
Artigo em Chinês | WPRIM | ID: wpr-615282

RESUMO

Purpose To investigate the value of MRI T2 mapping imaging in diagnosis of lumbar intervertebral disc degenerative (IVDD).Materials and Methods A prospective study was performed on 100 patients who underwent 1.5T MRI examination because of lumbar and back pain from October 2013 to December 2015 at the Fifth People's Hospital of Shanghai,Fudan University.The MRI examinations included conventional sagittal T1WI and T2WI,axial T2WI and median sagittal T2 mapping imaging.According to Pfirrmann standard,475 lumbar intervertebral discs were graded.T2 values of nucleus pulposus (NP) and annulus fibrosus (AF) of anteriority and posterior with different grades were measured and compared.The correlations between T2 value,age and grade were further analyzed.30 patients were selected and underwent a second MR examination after half a year,and the difference of T2 values between the two MR examinations were compared.Results Except for grade Ⅳ and grade Ⅴ,the differences of T2 values of NP between the other grades of lumbar intervertebral discs were statistically significant (P<0.05).T2 values of NP were negatively correlated with the grades (r=-0.77).There were no significant differences in T2 values of NP and AF of anteriority and posterior in 30 patients with back pain between the two MR measurements of half year interval (P>0.05).Conclusion T2 mapping imaging can quantitatively assess the degree of IVDD,especially T2 values of NP can reflect the differences of IVDD with grade Ⅰ-Ⅳ,so it can provide the imaging evidence for the diagnosis of IVDD.

5.
Chinese Journal of Interventional Cardiology ; (4): 515-520, 2016.
Artigo em Chinês | WPRIM | ID: wpr-504029

RESUMO

Objective To assess the efficacy and safety of antiplatelet threapy after transcatheter aortic valve implantation.Methods Databases including PubMed , EMBASE, MEDLINE, the Cochrane Library, CMB and CNKI were searched to collect the randomized controlled trials ( RCTs) and cohort study trials ( CSTs ) about the efficacy and safety of antiplatelet threapy after transcatheter aortic valve implantation.The literature was screened according to the inclusive and exclusive criteria by two reviewers independently.The quality was evaluated.The data were extracted and meta-analyses were performed by using RevMan 5.3 software.Results 4 trials were included, of which 2 were RCTs involving 199 patients, and 2 were cohort studies involving 441 patients.Efficacy analysis showed that there were no differences between mono versus dual antiplatelet therapy in terms of 30-day rates of stroke ( OR 0.55 ,95%CI:0.22-1.35 ,P =0.19 ) , myocardial infarction ( OR 1.70 , 95% CI:0.25 -11.65 , P =0.59 ) , and all-cause mortality ( OR 0.77 , 95% CI:0.40 -1.49 , P =0.44 ) .Safety analysis showed that mono antiplatelet therapy had lower incidence of bleeding events , compared to dual antiplatelet therapy ( OR 0.37 , 95%CI:0.23-0.59,P<0.0001).Conclusions Mono versus dual antiplatelet therapy in the prevention of stroke , myocardial infarction and all-cause mortality after TAVI has similar protective effects .Mono antiplatelet threapy presents lower bleeding event rate .Due to limited quality and quantity of the included studies , the above conclusions need to be verified by more high quality studies .

6.
Journal of International Pharmaceutical Research ; (6): 753-756, 2016.
Artigo em Chinês | WPRIM | ID: wpr-498128

RESUMO

Objective To develop a LC-MS/MS method for the quantification of empagliflozin(EPLZ)impurity X(EPLZ-X) in EPLZ pharmaceutical product. Methods Isocratic chromatographic separation was performed on a Thermo BDS C18 column(4.6 mm × 100 mm,2.4mm). The mobile phase consisting of acetonitrile-water(75∶25,V/V)was eluted at a flow rate of 0.7 ml/min. ESI source was applied and operated in the positive ion mode. multiple reaction monitoring(MRM)mode with the transitions of m/z 785→m/z 475 and m/z 785→m/z 418 were used to quantify the EPLZ-X. Results The method was linar in the concentration range from 0.5 to 100.6 ng/ml. The limit of quantification was 0.5 ng/ml. The intra-and inter-day precision values were both below 11.8%,and accuracy was within ±2.5%in all quality control samples. The average recovery was 105.1%、109.8%and 102.6%,respectively. Conclusion The method provides a sensitive and specific means for the determination of EPLZ-X in EPLZ pharmaceutical substances and completely meets the requirement of European Medicines Evaluation Agency(EMEA)(a limit of not more than 60×10-6 g for the mutagenic impurity EPLZ-X).

7.
Chinese Journal of Rheumatology ; (12): 846-850, 2011.
Artigo em Chinês | WPRIM | ID: wpr-423275

RESUMO

Objective To investigate the expression levels of phospholipase C(PLC)-γ1 and PLC-γ2 in the peripheral blood mononuclear cells (PBMCs) of patients with systemic lupus erythematosus (SLE),and explore the relations between these genes expression levels and disease activity of SLE.Methods Reverse transcription polymerase chain reaction (RT-PCR) method was used to detect the expression levels of PLC-γ1 and PLC-γ2 in 30 patients with SLE and 25 controls.The associations between the expression levels of PLC- γ1 and PLC-γ2,complement C3,C4,antidouble stranded DNA antibody and SLEDAI scores in patients with SLE were analyzed by Pearson correlation analysis.Results ①The expression levels of PLC-γ1 and PLC-γ2 in the SLE patients were significantly higher than those of the normal controls (P<0.01).) The expression levels of PLC-γ1 and PLC-γ2 showed positive correlations with each other (r=0.726,P<0.01 ).③ The expression levels of PLC-γ2 were negatively correlated with serum complement C3,C4 (P<0.05),but positively correlated with anti-double stranded DNA antibody,at the same time,they were not correlated with SLEDAI scores (P>0.05).There was no correlation between complement C3,C4,anti-double stranded DNA antibody and the expression levels of PLC-γ1 (r=0.220,0.256,0.116,P>0.05),but the expression levels of PLC-γ1 were positively correlated with SLEDAI scores.Conclusion We have shown that the expression levels of PLC-γ1 and PLC-γ2 is positively correlated and the PLC-γ1 and PLC-γ2 in patients with SLE are significantly higher than those of the normal controls.PLC-γ2 is negatively associated with complement C3,C4,PLC-γ1 is positively correlated with SLEDAI scores.Both PLC-γ1 and PLC-γ2 are be helpful in evaluating SLE disease activity and severity.

8.
Chinese Journal of Rehabilitation Theory and Practice ; (12): 583-584, 2010.
Artigo em Chinês | WPRIM | ID: wpr-961358

RESUMO

@#ObjectiveTo investigate the relation between morning blood pressure surge(MBPS) and myocardial ischemia.Methods315 patients with primary hypertension and coronary heart disease were received Holter and non-invasive ambulatory blood pressure monitoring(ABPM). According to the morning blood pressure raised, they were divided into MBPS group and no-MBPS group. Then the ABPM and Holter data were compared.ResultsThe patients in MBPS group were older. The myocardial ischemia events were more common in MBPS group than in no-MBPS group. The logistic regress showed that the MBPS was related to myocardial ischemia events even after corrected by age, smoke, and sex.ConclusionMBPS is a risk factor of myocardial ischemia.

9.
Chinese Medical Equipment Journal ; (6)2004.
Artigo em Chinês | WPRIM | ID: wpr-585194

RESUMO

USB interface chip PDIUSBD12 and Microchip's single chip processor PIC16F877 are applied to achieving computerized multi-channel data acquisition, and then a detection system of multi-channel physiological parameters of uterine cavity is designed on the basis of the above-mentioned. Being plug-and-play, real-time and general-purpose, this system can meet the requirement of medical research on the relationship between these parameters and diseases of uterine cavity.

10.
Journal of Chinese Physician ; (12)2001.
Artigo em Chinês | WPRIM | ID: wpr-522576

RESUMO

Objective To investigate whether the geometry of the left heart and the diastolic function of left ventricle change in patients with essential hypertension but without left ventricular remodeling. Methods Echocardiography was performed in consecutive male patients above 35 years old and without valvular heart disease, myocardial infarction, cardiomyopathy or other diseases that may have effect on the heart structure. The thickness of intra-ventricular septum(IVST) and left ventricular posterior wall (LVPWT), the end-diastolic diameter of the left ventricle(LVEDD), left atrial anterior-posterior(LAAPD), long (LALD) and cross-sectional diameters(LACD) and area(LAA), early diastolic peak velocity(EPV) and atrial contraction peak velocity(APV) of the mitral valve flow were measured. EPV/APV ratio, left ventricular mass index(LVMI), relative wall thickness(RWT) were calculated. Patients with LVMI≥131g/m 2 and/or RWT≥0 44 were excluded from this study. The remaining patients were divided into 2 groups: the patients with essential hypertension were included in the no-remodeling group(group NR), while the patients without essential hypertention entered the normal control group (group NC). Student test was used to compare the variables between the two groups. Results There were 146 cases in group NC and 156 in group NR. IVST,LVPWT,LVEDD,LVMI,LAAPD,LALD,LACD and LAA of group NR were larger than those of group NC(P

11.
Journal of Practical Radiology ; (12)1992.
Artigo em Chinês | WPRIM | ID: wpr-542051

RESUMO

Objective To assess the quality of coronal multi-planar reconstructed versus direct coronal scan images and to confirm whether the multiplanar reconstructed image can replace coronal scan.Methods One hundred and sixteen patients with orbital and paranasalsinuses disease were examined with GE Lightspeed plus 4 slices helical CT.All patients had transvers scan,and the coronal multiplannarreconstructed images were reformatted basis on transverse scan.All reformatted and scanned images were evaluated by the senior radiologists.Results In 116 cases,simultaneously multiplanar reconstructed images were performed in 60 cases,the quality of reformatted coronal imageswas similar to direct coronal scan in revealing normal anatomy and lesions of orbit and paranasal sinuses,all images were excellent andimaging quality was grade Ⅰ.54 cases couldn't be undergone direct coronal scan but reformatted coronal images also acquired the effect of diagnosis(32 cases were grade Ⅰ and 3 cases were grade Ⅱ on quality).Conclusion Direct coronal scan can be substitued by multiplanar reconstruction of multi-slice helical CT scan for orbit and paranasal sinuses.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA